Quick analysis of zinc in manganese brass



When measuring zinc in manganese brass, when the manganese content is small, the Mn(l) can be oxidized into insoluble hydrated manganese dioxide in an ammoniacal medium using gold persulfate as the oxidant and separated, and the zinc can be measured. ; When the manganese content is high, such as ZHMn57-3-L, when the manganese content is above 2%, the literature states that potassium chlorate or persulfuric acid should be used as the oxidant in nitric acid medium. In this way, hydrated dioxide can also be obtained Manganese is separated from manganese, but the manganese separation is not complete. On this basis, this paper conducted a nitric acid medium, potassium chlorate dosage, heating time, and masking test of interfering ions after separation. The test showed that in order to ensure complete precipitation of hydrated manganese dioxide, concentrated nitric acid is needed, and dilute nitric acid should not be used. Potassium chlorate is used for separation. The filtrate after using persulfuric acid has been tested and found to contain very little manganese. The filtrate was masked with potassium fluoride, sulfide, barium chloride, etc., and under the acidity condition of pH ~ 5.5, it was treated with xylenol orange, olfactory Cresol green is a mixed indicator. EDTA is used for complex titration. This method is simple to operate. The accuracy of the analysis results meets the test requirements and can be used to determine zinc in nickel-free manganese brass.
1. Reagents and instruments
Barium chloride solution: 109·L-'
Sodium sulfate and sulfonate liquid: both are 1. Bao·Lyi'
Hexamethylenetetramine: 3009·IJ-'
Methyl orange, xylenol orange: both are g2·1zhouyi`
Ocresol green: 29·IJ-' (prepared with ethanol)
EDTA standard solution: 0.olm
2.Analysis method
Weigh 0.50009 of the sample into a 200ml high-neck beaker. Add 15ml of concentrated nitric acid. After the sample is completely dissolved, heat to drive out the nitrogen oxides. Remove and cool slightly. Add 0.59 of potassium chlorate. Boil for Zmin. Add water to about 150ml. Filter. In a 250ml measuring flask, dilute with water to the mark. Take 25ml of dry triangular beaker, add 25ml of water, 1ml of barium chloride, 10ml of sodium sulfate, 29ml of potassium fluoride, 10ml of sulfur, and add one drop of methyl orange indicator. Adjust with hexamethylenetetramine until the red color of the solution just disappears. .And overdose 10ml. Add 3 drops of Ocresol Green indicator and 5 drops of Xylenol Orange. Titrate with 0.olmol·I-EDTA standard solution until the solution just turns grass green as the end point, and use similar zinc content standards to convert Analysis results of the sample.
3. Selection of test conditions
(l) Acidity can be seen from the acid effect curve. When titrating zinc with EDTA standard solution, the required pH is >4. The xylenol orange indicator is purple when pH >6.1 and yellow when pH`6.1. The complex formed by xylenol orange and the metal ion zinc is red. Therefore, the acidity of the solution should be selected under the condition of 4<pH<6.1 during titration. This method uses the acidity condition of pH=5·5.
(2) The influence of the dosage of potassium chlorate and grinding acid is to completely separate manganese. Concentrated nitric acid must be used. It is not suitable to use dilute nitric acid. And the dosage of nitric acid should not be too large.
Less. Otherwise, after adding potassium chlorate, it is found that the solution is splashed out and the manganese separation is incomplete. After testing, use 15ml of concentrated nitric acid and potassium chlorate. () 59.
(3) To eliminate interfering ions, barium chloride greater than 10 times the lead content can be used to form lead sulfate with sodium sulfate for lead in dry copper alloys.
Barium mixed crystal precipitates, and this precipitate is much less soluble than lead sulfate. Dry tin, iron, and aluminum can be masked with potassium fluoride. When the iron and aluminum content is greater than 10,000, 509·L acetone can be used for masking. Copper can be masked with sulfur veins.
(4) Selection of indicator When xylenol orange is used as the indicator, it is not easy to titrate the end point of the solution from red to yellow when titrating with EDTA standard solution.
It is easy to observe. Especially when lead and barium sulfate precipitates in the titration solution, the end point cannot be observed. For this reason, the Ocresol Green indicator is selected to show the characteristic of green under pH - 5.5, and xylenol orange and Ocresol are used. For the green mixed indicator, when the titration reaches the end point, there is an obvious jump process. That is, the solution changes from purple-red to grass green, and the end point is more obvious.