What ASTM B111 and ASME SB111 Cover
ASTM B111 is the specification for copper and copper alloy seamless condenser tubes and ferrule stock, and ASME SB111 is the equivalent ASME specification used where the material is intended for pressure equipment. Together with the related tube and pipe specifications ASTM B75, ASTM B280, ASTM B68, ASME SB75, ASME SB280 and ASME SB68, they define the tube that carries cooling water, refrigerant and process fluid inside condensers, heat exchangers and similar equipment.
Copper C12000 seamless condenser tubing is bought against those specifications, which fix the grade of copper, the permissible analysis, the dimensions and tolerances, the temper or condition, and the tests the finished tube must pass. A purchase description of the form ASME SB111 C12000 therefore identifies both the rules the tube must satisfy and the exact material it is made from.
Why C12000 Copper Is Chosen for Condenser and Heat Exchanger Service
Copper C12000 is also known as deoxidised copper, and it contains copper at a minimum of 99.90 % with a small controlled phosphorus addition. The phosphorus removes residual oxygen from the melt, which is why the grade is chosen where the tube must be joined or formed without the risk that oxygen in the metal reacts with hydrogen at high temperature and embrittles the wall.
Thermal conductivity. C12000 transfers heat efficiently, so the surface area of a condenser or heat exchanger can be used to full effect and the temperature difference needed to move a given heat load stays small.
Corrosion resistance. The material performs well in fresh water, cooling water and many industrial fluids, which is the basis of a long tube life in condensers and refrigeration circuits.
Formability and ductility. C12000 tube can be expanded into tube sheets, bent and coiled, and produced in the wall thicknesses demanded by lighter equipment.
Cleanliness. Copper surfaces resist the growth of bacteria and fungi, a useful property in potable water, food processing and healthcare installations.
Dimensions, Conditions and Supplied Forms
C12000 seamless tubing is produced over a wide size range so that a single grade covers condenser, HVAC and general engineering duties.
| Item | Range or content |
|---|---|
| Standard | ASTM B111 / ASTM B75 / ASTM B280 / ASTM B68 / ASME SB111 / ASME SB75 / ASME SB280 / ASME SB68 |
| Material | Copper C12000 |
| Outer diameter | 4 mm to 150 mm |
| Wall thickness | 0.25 mm to 8 mm |
| Length | 1 m to 6 m, or as required |
| Types | Seamless tube and pipe, light drawn, light annealed, bright, annealed, fully annealed, hard drawn |
Tube is supplied as pancake coil and level wound coil for air-conditioning and refrigeration work, as straight lengths for condenser and heat exchanger bundles, and as inner-grooved tube where a larger internal surface area is required to raise heat transfer efficiency. Semi-finished tube is supplied for industrial conversion, and straight copper pipe is supplied for the transport of water, gas and oil.
Chemical Composition and Physical Properties
The composition of the grade is simple: high-purity copper with a closely controlled phosphorus content and silver counted within the copper figure.
| Grade | Cu, % | P, % |
|---|---|---|
| C12000 | min 99.90, including Ag | 0.004 to 0.012 |
The physical properties below are the values used when equipment is designed, and they reflect the high conductivity and stable behaviour of the grade at service temperature.
| Property | Value |
|---|---|
| Density | 0.323 lb per cubic inch |
| Electrical resistivity | 10.6 microhm-cm at 68 deg F |
| Melting point | 1981 deg F |
| Mean coefficient of thermal expansion | 9.4 (micro inch per inch per deg F) |
| Modulus of elasticity in tension | 17 000 ksi |
Manufacturing Route, Inspection and Applications
Seamless tube is produced from a cast and extruded shell rather than from strip that has been welded, so the finished wall has no longitudinal seam. The route runs through the following stages:
Melting and composition control of the copper charge, with phosphorus held inside the specified range.
Casting of the shell or billet, followed by extrusion to hollow or solid form.
Drawing and pilgering to reduce the wall and diameter to the ordered size.
Annealing to the ordered condition, from light drawn through to fully annealed.
Cutting to length, then inspection of dimensions, concentricity, surface and mechanical state.
Cleaning, capping and packing so that the bore reaches the site clean and dry.
The applications follow from those properties: condenser and heat exchanger tubes, refrigeration and air-conditioning coils, plumbing and HVAC systems, marine and offshore piping, architectural and interior work, automotive fluid lines, and electrical and fuel gas installations. Wherever heat has to move, water has to stay clean, or a joint has to remain reliable for decades, C12000 seamless tubing is one of the most economical answers available to an equipment designer.
Frequently Asked Questions
Q: What is the difference between ASTM B111 and ASME SB111 tubing?
Both describe the same copper and copper alloy seamless condenser tube and ferrule stock. ASTM B111 is the material specification, while ASME SB111 is the equivalent specification applied where the tube is used in pressure equipment.
Q: Why is C12000 called deoxidised copper?
Because a controlled phosphorus addition of 0.004 to 0.012 % removes residual oxygen from the melt. This prevents steam embrittlement when the tube is brazed, welded or heated in service.
Q: What sizes of C12000 tube can be supplied?
Outer diameter from 4 mm to 150 mm, wall thickness from 0.25 mm to 8 mm, and length from 1 m to 6 m. Other sizes can be produced to the requirements of the order.
Q: Which tempers are available for condenser tubing?
Light drawn, light annealed, annealed, fully annealed and hard drawn tube are all produced, along with bright annealed tube and inner-grooved tube for refrigeration and air-conditioning duty.
Q: How is C12000 tube checked before dispatch?
Dimensions, wall concentricity, surface condition and mechanical state are inspected, and the chemical composition is verified against the grade limits as part of the quality control routine.
Q: Is C12000 suitable for seawater and marine service?
It is widely used in marine and offshore piping and in condensers handling cooling water. Where chloride levels are high or flow conditions are aggressive, the wall thickness and the water treatment programme usually decide the tube life.