Gnee Steel (Tianjin) Co., Ltd.

T1 Copper Properties

May 27, 2026

Chemical composition and purity of 99.97% T1 oxygen-free copper

Element Requirement Typical Value
Copper (Cu) ≥99.97% 99.98-99.99%
Oxygen (O) ≤0.002% (20 ppm) <15 ppm
Phosphorus (P) ≤0.002% <0.001%
Iron (Fe) ≤0.004% <0.002%
Lead (Pb) ≤0.003% <0.001%
Antimony (Sb) ≤0.002% <0.001%
Arsenic (As) ≤0.002% <0.001%
Bismuth (Bi) ≤0.001% <0.0005%
Total impurities (excluding oxygen) ≤0.03% <0.02%

Every 0.01% of impurity reduces electrical and thermal conductivity. The 0.07% difference between T1 (99.97%) and T2 (99.90%) translates to about 1% higher conductivity and significantly better weldability.

T1 copper plate

 

Electrical conductivity of high-purity T1 copper in IACS

T1 copper has an electrical conductivity of ≥101% IACS at 20°C.

Electrical Property Value
Conductivity (% IACS) ≥101%
Resistivity at 20°C (Ω·mm²/m) ≤0.01707
Conductivity at 100°C ~95% IACS
Conductivity at 200°C ~85% IACS

 

How T1 compares to other grades:

Grade Conductivity (% IACS) Difference
T1 copper ≥101% Baseline
T2 copper ≥100% -1%
ASTM C10200 ≥100% -1%
ASTM C11000 100% -1%
Pure silver 105% +4%
Aluminum 6061 61% -40%

For a busbar carrying 1000 amps, T1 generates about 1% less heat than C11000. For most applications, this difference is negligible. For high-current switchgear or efficiency-critical systems, it is a real advantage.

 

Thermal conductivity and heat transfer of oxygen-free copper grade

T1 copper has a thermal conductivity of approximately 391 W/(m·K) at 20°C.

Thermal Property Value
Thermal conductivity at 20°C ~391 W/(m·K)
Thermal conductivity at 100°C ~385 W/(m·K)
Thermal conductivity at 200°C ~375 W/(m·K)
Thermal diffusivity ~115 mm²/s
Specific heat capacity 0.385 J/(g·K)

 

How T1 compares to other materials:

Material Thermal Conductivity (W/(m·K))
T1 copper ~391
Silver 429
T2 copper ~385
ASTM C11000 ~385
Aluminum 6061 167
Brass 70/30 120
Stainless steel 304 15

Applications where thermal performance matters: Heat exchangers, cooling plates, LED heat sinks, power electronics cooling, cryogenic transfer lines, and radiator cores.

 

Tensile strength and mechanical properties

Annealed (soft) condition - most common for forming and stamping:

Property Value
Tensile strength 200 - 250 MPa (29 - 36 ksi)
Yield strength (0.2% offset) 40 - 60 MPa (6 - 9 ksi)
Elongation (in 50mm) ≥30%
Hardness (Vickers, HV) 40 - 60
Hardness (Rockwell F) 40 - 55

 

Half-hard condition - moderate strength with some formability:

Property Value
Tensile strength 250 - 300 MPa (36 - 44 ksi)
Yield strength (0.2% offset) 150 - 200 MPa (22 - 29 ksi)
Elongation (in 50mm) 10% - 20%
Hardness (Vickers, HV) 70 - 90

 

Hard (full hard) condition - maximum strength, minimum ductility:

Property Value
Tensile strength 300 - 360 MPa (44 - 52 ksi)
Yield strength (0.2% offset) 250 - 300 MPa (36 - 44 ksi)
Elongation (in 50mm) 2% - 6%
Hardness (Vickers, HV) 90 - 110

 

How to choose the right temper:

If you need... Choose...
Deep drawing, complex stamping, tight bends Annealed
General fabrication, moderate forming Half-hard
Spring contacts, structural busbars, maximum stiffness Hard

 

T1 Copper  Physical properties

Physical Property Value
Density at 20°C 8.94 g/cm³ (0.323 lb/in³)
Melting point 1083°C (1981°F)
Specific heat capacity at 20°C 0.385 J/(g·K)
Coefficient of thermal expansion (20-300°C) 17.0 × 10⁻⁶ /K
Modulus of elasticity (Young's modulus) 115 - 130 GPa (16.7 - 18.9 msi)
Modulus of rigidity (shear modulus) 44 - 48 GPa
Poisson's ratio 0.34 - 0.35
Electrical resistivity at 20°C ≤0.01707 Ω·mm²/m
Thermal diffusivity ~115 mm²/s

 

Practical implications:

Density 8.94 g/cm³: A 1m x 1m x 1mm sheet weighs 8.94 kg. Use this for shipping and structural calculations.

Melting point 1083°C: Well above brazing temperatures (600-800°C) and soldering temperatures (200-400°C). No risk of melting during joining.

Thermal expansion 17 ppm/K: A 1m long busbar heated from 20°C to 80°C expands by about 1mm. Account for this in mounting systems.

 

Weldability and joining specifications for T1 copper

T1 copper has excellent weldability due to its low oxygen content.

Joining Method Suitability Notes
TIG welding Excellent No flux needed, clean welds, no porosity
MIG welding Excellent Use deoxidized filler wire (ERCu)
Resistance welding Excellent Consistent results, no oxidation issues
Brazing Excellent Flows well, strong joints
Soldering Excellent Easy to wet, strong bonds
Mechanical joining Excellent Bolts, rivets, crimps all work

 

Recommended TIG welding parameters for T1 copper sheet:

Thickness Tungsten Size Amperage (DCEN) Filler Rod
1mm 1.6mm 80-120 A ERCu
2mm 2.4mm 150-200 A ERCu
3mm 3.2mm 220-280 A ERCu
5mm 4.0mm 300-400 A ERCu

Why T1 welds better than T2 or C11000: Those grades contain 200-500 ppm oxygen. During welding, oxygen reacts with hydrogen to form water vapor, creating porosity in the weld. T1 has almost no oxygen, so no porosity, no embrittlement, no cracking.

 

Cryogenic performance of t1 copper at low temperatures

T1 copper performs excellently at cryogenic temperatures and has no ductile-to-brittle transition.

Conductivity at cryogenic temperatures:

Temperature Conductivity (% IACS) Notes
20°C (room temperature) ≥101% Baseline
-196°C (liquid nitrogen) ~300% Increases dramatically
-269°C (liquid helium) ~500% Near theoretical maximum

 

Mechanical properties at cryogenic temperatures:

Temperature Tensile Strength Elongation
20°C 200-250 MPa ≥30%
-196°C ~400 MPa ~40%
-269°C ~500 MPa ~30%

 

Why T1 is preferred for cryogenic systems:

No ductile-to-brittle transition (unlike steel)

Strength increases as temperature drops

Ductility remains high

Thermal conductivity becomes extremely high

No embrittlement from impurities (purity matters at low temperatures)

 

Applications: Liquid nitrogen transfer lines, liquid helium transfer lines, cryostat components, cold heads for cryocoolers, thermal straps, superconducting magnet supports, space-based instruments.

 

Corrosion resistance of 99.97% T1 pure copper in various environments

T1 copper has excellent corrosion resistance in many common environments.

Environment Corrosion Resistance Notes
Atmospheric (rural) Excellent Forms protective patina
Atmospheric (industrial) Good Patina forms, may be darker
Atmospheric (marine) Fair to good Can pit in salt spray
Fresh water Excellent Safe for potable water
Distilled water Good Very low corrosion rate
Seawater Fair Pitting and erosion possible
Neutral salt solutions Good Similar to fresh water
Non-oxidizing acids Fair Depends on concentration
Oxidizing acids (nitric, concentrated sulfuric) Poor Not recommended
Ammonia and ammonium compounds Poor Causes stress corrosion cracking

Corrosion rates for reference:

In rural atmosphere: <0.001 mm/year

In industrial atmosphere: 0.001-0.005 mm/year

In fresh water: 0.002-0.005 mm/year

In seawater: 0.01-0.05 mm/year (with pitting risk)

 

Dimensional tolerances per GB/T 5231 for t1 copper sheet and rod

Sheet and plate thickness tolerances (annealed):

Thickness (mm) Tolerance (± mm)
0.1 - 0.5 0.02 - 0.05
0.5 - 1.0 0.05 - 0.08
1.0 - 2.0 0.08 - 0.12
2.0 - 5.0 0.12 - 0.20
5.0 - 10.0 0.20 - 0.30
10.0 - 20.0 0.30 - 0.50
20.0 - 50.0 0.50 - 1.00

 

Round rod diameter tolerances:

Diameter (mm) Tolerance (± mm)
1 - 10 0.03 - 0.08
10 - 30 0.08 - 0.15
30 - 60 0.15 - 0.25
60 - 100 0.25 - 0.40

 

Strip width tolerances (slit edge):

Width (mm) Tolerance (± mm)
Up to 100 0.10 - 0.20
100 - 300 0.20 - 0.40
300 - 600 0.40 - 0.80

 

T1 VS T2 Copper

Property T1 Copper T2 Copper ASTM C10200 ASTM C11000
Minimum Cu (%) 99.97 99.90 99.95 99.90
Oxygen content (ppm) <20 200-500 <20 200-500
Oxygen-free? Yes No Yes No
Conductivity (% IACS) ≥101 ≥100 ≥100 100
Thermal conductivity (W/m·K) ~391 ~385 ~391 ~385
Tensile strength annealed (MPa) 200-250 200-250 200-250 200-250
Elongation annealed (%) ≥30 ≥30 ≥30 ≥30
Weldability Excellent Fair Excellent Poor
Hydrogen embrittlement risk None High None High
Vacuum outgassing Very low Moderate Very low Moderate
Relative price Higher Lower Highest Low

 

Quick selection guide:

If you need... Choose...
Oxygen-free copper T1 or C10200
Highest conductivity T1
Weldability T1 or C10200
Lowest cost for general use T2 or C11000
ASTM-certified material C10200 or C11000
Chinese material at good price T1 for demanding, T2 for general

 

FAQ

1. What is the electrical conductivity of T1 copper?

T1 copper has electrical conductivity of ≥101% IACS at 20°C. This is higher than standard C11000 electrolytic copper (100% IACS) and comparable to other oxygen-free coppers. The high conductivity comes from the 99.97% purity and extremely low impurity levels.

 

2. What is the thermal conductivity of T1 copper?

T1 copper has thermal conductivity of approximately 391 W/(m·K) at 20°C. This is one of the highest values among engineering metals, second only to silver. For comparison, aluminum 6061 is 167 W/(m·K) and stainless steel 304 is 15 W/(m·K).

 

3. What is the tensile strength of T1 copper?

The tensile strength depends on temper. Annealed T1 has 200-250 MPa (29-36 ksi). Half-hard has 250-300 MPa (36-44 ksi). Hard (full hard) has 300-360 MPa (44-52 ksi). Most T1 sheet and strip is supplied annealed unless specified otherwise.

 

4. Is T1 copper magnetic?

No, T1 copper is not magnetic. Copper is diamagnetic, meaning it is very weakly repelled by magnetic fields. For practical purposes, T1 copper is non-magnetic and can be used in MRI machines, sensitive electronic equipment, and any application where magnetic materials are prohibited.

 

5. What is the melting point of T1 copper?

T1 copper melts at 1083°C (1981°F). This is standard for pure copper. The melting point is well above brazing temperatures (600-800°C) and soldering temperatures (200-400°C), so there is no risk of melting during normal joining processes.

 

6. What is the density of T1 copper?

T1 copper has density of 8.94 g/cm³ at 20°C (0.323 lb/in³). A 1m x 1m x 1mm sheet weighs 8.94 kg. A 1m long 10mm diameter rod weighs about 0.7 kg. Use these numbers for shipping calculations and structural design.

 

7. Can T1 copper be heat treated?

No, pure copper like T1 cannot be heat treated for strengthening. Unlike steel or aluminum alloys, pure copper does not respond to heat treatment. Strength is achieved only through cold working (rolling, drawing). Annealing softens the material by removing the effects of cold work.

 

8. What is the hardness of T1 copper?

Hardness depends on temper. Annealed T1 has Vickers hardness of 40-60 HV. Half-hard is 70-90 HV. Hard (full hard) is 90-110 HV. For reference, annealed T1 is very soft and can be scratched with a fingernail. Hard T1 is significantly stiffer but still machinable.

 

9. Does T1 copper corrode?

T1 copper has excellent corrosion resistance in air, fresh water, and neutral salt solutions. It forms a protective patina over time. However, it corrodes in strong oxidizing acids (nitric acid, concentrated sulfuric acid), ammonia solutions, and seawater (pitting risk). For most indoor electrical applications, corrosion is not a concern.

 

10. What is the modulus of elasticity of T1 copper?

The modulus of elasticity (Young's modulus) of T1 copper is 115-130 GPa (16.7-18.9 msi). This is standard for all copper grades. It is about one-third the modulus of steel (200 GPa), meaning copper is about three times more flexible than steel under the same load.

 

11. What is the coefficient of thermal expansion of T1 copper?

T1 copper has coefficient of thermal expansion of 17.0 × 10⁻⁶ /K from 20-300°C. This means a 1m long copper bar expands by 0.017mm for every 1°C temperature increase. For a 1m bar heating from 20°C to 80°C, expansion is about 1mm. Always account for thermal expansion in long busbar runs.