Composition and the Role of Oxygen
C10200 is defined by two numbers rather than one: copper at 99.95 % minimum and oxygen at 0.0010 % maximum, with the total of all other impurities held at or below 0.05 %. That combination is what separates the grade from tough pitch copper, which deliberately retains 0.02 - 0.05 % oxygen. The ultra low oxygen level prevents the formation of steam pockets if the material is heated in a reducing atmosphere such as hydrogen, which is the failure mode known as hydrogen embrittlement. Parts that are brazed, welded or bright annealed therefore keep their integrity instead of developing internal cracks.
Physical Properties
| Property | Value | Notes |
|---|---|---|
| Density | 8.94 g/cm³ (0.323 lb/in³) | At 20 °C |
| Melting point | 1083 °C (1981 °F) | - |
| Electrical conductivity | 101 % IACS minimum | International annealed copper standard |
| Volume conductivity | About 58.6 MS/m | At 20 °C |
| Electrical resistivity | 1.724 µΩ·cm | Theoretical minimum at 20 °C |
| Thermal conductivity | 391 W/(m·K) | At 20 °C |
| Coefficient of thermal expansion | 16.7 x 10⁻⁶ per K | 20 - 100 °C range |
| Modulus of elasticity | 115 - 130 GPa | - |
These values place C10200 in the small group of metals that conduct both electricity and heat at the highest commercial level. The thermal conductivity figure is roughly nine times that of carbon steel, which is why the grade is used for heat exchanger and cooling equipment as well as for conductors.
Mechanical Properties by Temper
C10200 is commonly supplied in the annealed tempers for maximum ductility, and can be cold worked to higher strengths where stiffness is needed. The values below follow the temper ranges used for the grade in ASTM B152 flat product, and the same trends apply to tube and bar.
| Temper / condition | Tensile strength, MPa | Yield strength 0.5 % extension, MPa | Elongation, % | Hardness, Rockwell F |
|---|---|---|---|---|
| Annealed (O60) | 200 - 240 | 35 - 70 | 45 - 60 | 35 - 45 |
| Cold worked, medium (H04) | 260 - 300 | 200 - 240 | 20 - 30 | 65 - 75 |
| Cold worked, high (H08) | 340 - 380 | 310 - 345 | 4 - 12 | 80 - 90 |
Selecting the temper is a balance between formability and strength. Annealed material bends, flanges, stamps and coins without cracking and is the right choice where the part is formed after delivery. Heavily cold worked material carries higher strength and hardness but very limited elongation, so it is used for parts that are finished to size before delivery, such as strip conductors and machined components.
Advantages in Service
Immunity to hydrogen embrittlement, because the oxygen level is capped at 0.0010 %.
Excellent ductility and workability in cold and hot processes including rolling, drawing, stamping and forging.
Good weldability and brazability with the common processes, without special atmosphere restrictions.
Bright, clean surface after annealing, suitable for plating and for vacuum service.
Good resistance to atmospheric corrosion, fresh water and non-oxidising acids, with tarnishing in sulphur bearing atmospheres.
Supply, Inspection and Ordering Notes
The grade is supplied as tube and pipe, plate, sheet, strip, coil, bar, rod, wire and bus bar, and in fabricated forms such as U-bend tube and finned tube, with dimensions produced to drawing. Typical uses include heat exchangers and cooling systems, electrical bus bars and conductors, vacuum and electronic components, refrigeration and air conditioning circuits, and general equipment that combines corrosion resistance with conductivity.
On a C10200 order the inspection plan covers chemical composition by spectrometer with a specific check on oxygen, electrical conductivity measurement, tensile testing to confirm the temper, hardness testing on flat product, grain size measurement on annealed material, dimensional and thickness tolerance checks, and surface or eddy current inspection where the application requires it. Each heat is certified with composition, conductivity and mechanical results, and packing is designed for sea, air and courier transport with protective film and wooden cases or strapped bundles.
Frequently Asked Questions
Q: What is the oxygen content of C10200?
A: A maximum of 0.0010 %, with copper at 99.95 % minimum. That low oxygen level is what makes the material immune to hydrogen embrittlement.
Q: What is the conductivity of C10200?
A: At least 101 % IACS, equivalent to about 58.6 MS/m by volume and a resistivity of roughly 1.724 µΩ·cm at 20 °C.
Q: Which tempers are available?
A: Annealed O60 for maximum ductility, cold worked H04 for medium strength and cold worked H08 for high strength, with elongation falling from 45 - 60 % in the annealed condition to 4 - 12 % in the hardest temper.
Q: Why is C10200 better than C11000 for brazed assemblies?
A: C11000 retains 0.02 - 0.05 % oxygen, which can cause hydrogen embrittlement during heating in a reducing atmosphere. C10200 contains almost no oxygen, so brazed and annealed assemblies remain sound.
Q: What is the thermal conductivity?
A: About 391 W/(m·K) at 20 °C, one of the highest values available in a commercial engineering metal.
Q: How is the material certified?
A: Each heat is certified with chemical composition including the oxygen check, electrical conductivity and mechanical test results, and dimensional or eddy current test reports are added when the order requires them.