Cu-PHC (CW020A): Phosphorus-Containing High Conductivity Copper

Dec 01, 2023

What Is Cu-PHC

Cu-PHC, material number CW020A, is a phosphorus-containing high-conductivity copper grade used for general electrical purposes. It is covered by EN 13601 for rod, bar, and wire, EN 13600 for seamless tubes, EN 13599 for plate, sheet, and strip, EN 13605 for profiles and profiled wire, and EN 13148 for hot-dip tinned strip, all for electrical applications, with EN 1976 for cast unwrought products.

Chemical Composition

The composition limits are phosphorus 0.001 to 0.006 percent, copper minimum 99.95 percent, lead maximum 0.005 percent, bismuth maximum 0.0005 percent, and other elements total maximum 0.03 percent. The small phosphorus addition deoxidizes the melt, reducing oxygen content and improving weldability while maintaining high conductivity.

Mechanical Properties

In the R220 condition the tensile strength is 220 to 260 MPa with proof strength of 140 MPa and elongation of 33 percent in 50 mm. In the R290 condition the tensile strength is 290 to 360 MPa with proof strength of 250 MPa. In the R350 condition the tensile strength is 350 MPa with proof strength of 320 MPa and elongation of 5 percent. Vickers hardness ranges from 40 to 65 HV in H040, 90 to 110 HV in H090, and 100 HB in H100. Density is 8.9 g per cubic centimeter.

Electrical Properties

The volume resistivity of Cu-PHC is 0.01724 to 0.01786 ohm square millimeters per meter, corresponding to a minimum conductivity of about 96 percent IACS. The controlled phosphorus content keeps conductivity high while providing deoxidation benefits.

Applications

Cu-PHC is used for electrical conductors, busbars, transformer windings, switchgear, tinned strip for electrical terminals, and other electrical components requiring high conductivity combined with good weldability and formability.

Frequently Asked Questions

Q: What does PHC stand for?

A: Phosphorus-containing high conductivity.

Q: What is the phosphorus range?

A: 0.001 to 0.006 percent.

Q: What is the copper content?

A: Minimum 99.95 percent.

Q: What conditions are available?

A: R220, R290, and R350 with H040, H090, and H100 hardness conditions.

Q: What standards cover Cu-PHC?

A: EN 13600, 13601, 13599, 13605, and 13148.

Q: What is the volume resistivity?

A: 0.01724 to 0.01786 ohm square millimeters per meter.

Contact us for Cu-PHC CW020A rod, wire, strip, and tube with certified properties.