Gnee Steel (Tianjin) Co., Ltd.

C11000 Copper Pipe: Composition, Properties and Applications

Nov 27, 2025

What C11000 Copper Pipe Is

C11000 is electrolytic tough pitch copper, designated Cu-ETP in the European system and C1100 in the Japanese system. It is the workhorse copper of the tube and pipe trade: at least 99.90 percent copper, with oxygen deliberately retained in the range of 0.02 to 0.04 percent rather than removed. That residual oxygen is what makes the grade economical to cast and roll, and it does not harm conductivity, which stays at the 100 to 101 percent IACS level. A pipe made from C11000 therefore combines high electrical and thermal conductivity with the ductility needed for bending, flaring and expanding into tube sheets, and it resists fresh water, seawater, mildly acidic and alkaline service through its natural protective oxide film.

C11000 should not be confused with the oxygen-free grades C10100 and C10200. Oxygen-free copper is chosen when the tube will be welded or brazed, or exposed to a reducing atmosphere at high temperature, because oxygen-bearing copper can suffer hydrogen embrittlement in those conditions. For ordinary water, refrigerant, drainage and electrical duty, C11000 is the normal and more economical choice.

Composition, Temper and Mechanical Properties

Element C11000 requirement
Copper (Cu) 99.90 % minimum
Oxygen (O) 0.040 % maximum, typically 0.02-0.04 %
Total other elements 0.10 % maximum

Temper controls strength and formability more than composition does. Pipe is ordered in soft, half hard or hard temper depending on whether it will be bent in the field or must hold straightness and pressure rating as supplied.

Temper Tensile strength, typical Yield strength, typical Elongation, typical Typical duty
Soft annealed O60 220-260 MPa 69-150 MPa 40-50 % Field bending, flaring, coil tube
Half hard H02 260-320 MPa 250-280 MPa 20-30 % Straight runs, moderate pressure
Hard H04 320-380 MPa 310-345 MPa 8-15 % High pressure, thin wall, minimum support

Physical Properties That Guide Application Choice

Property Value
Density 8.91 g/cm3 at 20 C
Melting range 1065-1083 C
Electrical conductivity 101 % IACS at 20 C
Electrical resistivity 0.0171 ohm mm2/m at 20 C
Thermal conductivity 391 W/mK at 20 C
Coefficient of thermal expansion 16.9 µm/mK from 20 to 100 C
Modulus of elasticity 117 GPa in tension
Specific heat capacity 385 J/kgK at 20 C

Two values dominate selection decisions. Conductivity of 101 percent IACS makes C11000 the reference conductor material for wiring, earthing and bus connections. Thermal conductivity of roughly 391 W/mK, an order of magnitude higher than stainless steel, makes the same pipe the default choice for heat exchanger, condenser and refrigeration circuits where heat must move quickly through a thin wall.

Standards, Sizes and Fabrication

ASTM B75 covers seamless copper tube for general engineering service, the broadest specification for C11000 tube.

ASTM B88 covers copper water tube in types K, L and M with different wall thicknesses for buried, general and interior plumbing duty.

ASTM B280 covers refrigeration and air conditioning tube, supplied cleaned and capped for ACR service.

EN 1057 covers copper tube for water, gas and sanitary applications in European practice, and GB/T 1527 covers drawn copper and copper alloy tube.

Hard temper tube is supplied straight in lengths up to about 6 m; soft temper is coiled for plumbing and instrument runs.

C11000 is readily bent, flared, expanded and soldered, but welded fabrication calls for oxygen-free grades or silver-bearing copper.

Typical Applications by Industry

Building services: potable water supply, hot water circulation, drainage, rainwater and fire sprinkler pipework.

HVAC and refrigeration: condenser, evaporator and refrigerant line tube, plus chiller and heat pump circuits.

Process industry: shell and tube heat exchangers, condensers, boiler feedwater and steam-water separator piping, pressure vessel internals.

Electrical and electronic: earthing and lightning protection conductors, bus connections, transformer and instrument components, shielding for sensitive equipment.

Medical and laboratory: clean-bore gas and fluid lines in healthcare and laboratory installations.

Water treatment: plant piping for filtration and chemical dosing where corrosion resistance matters more than pressure rating.

Where the duty involves aggressive chlorides or ammonia, a corrosion-resistant copper alloy such as C70600 or C71500 is used instead, but for the majority of water, refrigerant and electrical applications C11000 pipe remains the standard specification.

Frequently Asked Questions

Q: Is C11000 the same as oxygen-free copper?
No. C11000 is electrolytic tough pitch copper that contains 0.02 to 0.04 percent oxygen. Oxygen-free copper is C10100 or C10200, with oxygen held below about 0.001 percent, and it is selected for welding and high temperature reducing service.

Q: What does 101 percent IACS mean?
IACS stands for International Annealed Copper Standard, which fixes 100 percent to a resistivity of 0.017241 ohm mm2/m at 20 C. A reading of 101 percent IACS means the material conducts slightly better than that baseline, which is typical for clean C11000.

Q: Which temper should be ordered for plumbing work?
Soft annealed O60 temper is normal for plumbing and instrument tube because it bends and flares without cracking. Half hard or hard temper is ordered for straight runs that must resist sagging and hold a higher pressure rating.

Q: Can C11000 pipe be welded?
It can be welded, but the residual oxygen makes the joint prone to hydrogen embrittlement, especially with reducing shielding gases. For welded fabrication, oxygen-free C10200 or silver-bearing copper is normally specified instead.

Q: How is copper pipe performance verified before delivery?
By spectrometer analysis for composition and conductivity, tensile testing for temper, eddy current testing for surface and near-surface defects, dimensional gauging for wall and ovality, and hydrostatic pressure testing for pressure duty.

Q: Why is copper preferred over stainless steel for heat exchanger tubes?
Because its thermal conductivity of about 391 W/mK is roughly an order of magnitude higher than stainless steel, so a thinner wall moves the same heat duty. Copper also resists the chloride-bearing cooling waters that cause pitting in many stainless grades.

goTop