Gnee Steel (Tianjin) Co., Ltd.

Air conditioning copper pipe laying design and attention points

Oct 08, 2023

Air conditioning copper pipe

1. Air-conditioning copper pipe can be installed openly, dark installation, recommended dark installation. The main reasons: 1) copper piping installed in the open, in certain environmental conditions will generate copper green on the outer surface of the copper pipe, affecting the aesthetic; 2) copper pipe material is soft, such as open laying, copper piping may be pulled, climbing, hanging, stirrups, touching and so on, leading to deformation of the copper pipe, resulting in leakage.

2. Trunk and riser should be concealed in the ceiling, tube wells, pipe holes; branch pipe should be laid in the ground leveling layer, decorative wall or pipe groove cut along the wall. Pipes laid in the pipe groove, the pipe diameter shall not be greater than DN25 (Note: the national architectural standard design drawings set for DN20), and should be used for plastic-coated copper pipe, groove copper pipe should be fixed measures.

3. Riser should be arranged in the water consumption of sanitary appliances or equipment nearby. Buildings should be designed into a ring-shaped pipe network.

4. Avoid the arrangement of independent or little water supply of long-distance branch trunk pipe. Such an arrangement will make the part of the pipeline for a long time in the stagnant flow or semi-stagnant flow state, easy to lead to corrosion of the pipeline hole

5. In order to avoid or reduce galvanic corrosion, in the copper piping system, do not connect ordinary carbon steel pipe. If so, insulation should be made at the connection. Copper flange and steel flange connection, non-copper material groove connectors at the groove, should be in its contact with the copper material, take the necessary insulation measures for corrosion protection. Recommended piping system overall use of copper (including copper valves and copper alloy support parts, etc.). Electrochemical corrosion of metals is mainly due to the presence of CO2, SO2, NH2, O2 and other components in the atmosphere, and the presence of dust, corrosion and scars on the surface of pipelines. And different kinds of metal materials have different potentials, chemical composition and internal organization of materials are different. When there is an electrolyte solution on the contact surface, the more active metal atoms lose electrons and are oxidized and corroded. Note: This measure is mainly to prevent galvanic corrosion on the carbon steel side. Copper side of the electrode potential of copper is not easy to lose electrons, so it is not easy to corrode.

6. Purple copper pipe should not be poured in reinforced concrete structure. In addition to hard brazing and clamping type connection of copper pipe, the rest of the way to connect the copper pipe shall not be concealed in the wall groove or ground bedding. Reinforced concrete structure construction process, frequent cross operations, construction and hidden construction quality supervision, pipe pressure test difficult, if the pipe is buried in reinforced concrete components, once the pipe wall breakage, remedial difficulties. Therefore, the provisions of the copper water pipe should not be poured in reinforced concrete structure beams, slabs, columns.

7. Buried copper pipe should be plastic-coated copper pipe. Due to the copper water pipe for thin-walled pipe, laid directly in the backfill, recommended the use of plastic-coated copper pipe, in order to avoid soil corrosion of copper pipe acid or alkali corrosion or hard objects on the pipeline caused by mechanical damage. The burial depth of buried copper pipe should be determined by its upper load. In cold areas, the top of the pipe should be below the frost line.

8. Into house pipe should be laid for horizontal or vertical bending into house. Copper pipe thermal expansion system, bending into the home, can effectively eliminate the stress generated by the expansion of the pipeline.

9. Pipes through the floor, load-bearing walls, there should be a casing. Installation of the casing in the floor, the lower end should be flush with the floor, the top should be 20 ~ 50mm above the indoor floor. installation of the casing in the wall, the ends of the decorative surface and flat.

10. bathroom, kitchen and other water distribution branch, in the indoor floor matting or wall grooves can be used in parallel, series distribution of water distributor. No removable fittings are allowed on the water distributor pipe. Plastic-coated copper pipe is suitable. Compared with the traditional water distribution program, the water distributor water distribution program has good hydraulic conditions, improved water supply security, construction and installation of simple, but in the water distributor to be set at the exhaust valve.